7,451 research outputs found

    Age-related differences in adaptation during childhood: The influences of muscular power production and segmental energy flow caused by muscles

    Get PDF
    Acquisition of skillfulness is not only characterized by a task-appropriate application of muscular forces but also by the ability to adapt performance to changing task demands. Previous research suggests that there is a different developmental schedule for adaptation at the kinematic compared to the neuro-muscular level. The purpose of this study was to determine how age-related differences in neuro-muscular organization affect the mechanical construction of pedaling at different levels of the task. By quantifying the flow of segmental energy caused by muscles, we determined the muscular synergies that construct the movement outcome across movement speeds. Younger children (5-7 years; n = 11), older children (8-10 years; n = 8), and adults (22-31 years; n = 8) rode a stationary ergometer at five discrete cadences (60, 75, 90, 105, and 120 rpm) at 10% of their individually predicted peak power output. Using a forward dynamics simulation, we determined the muscular contributions to crank power, as well as muscular power delivered to the crank directly and indirectly (through energy absorption and transfer) during the downstroke and the upstroke of the crank cycle. We found significant age × cadence interactions for (1) peak muscular power at the hip joint [Wilks' Lambda = 0.441, F(8,42) = 2.65, p = 0.019] indicating that at high movement speeds children produced less peak power at the hip than adults, (2) muscular power delivered to the crank during the downstroke and the upstroke of the crank cycle [Wilks' Lambda = 0.399, F(8,42) = 3.07, p = 0.009] indicating that children delivered a greater proportion of the power to the crank during the upstroke when compared to adults, (3) hip power contribution to limb power [Wilks' Lambda = 0.454, F(8,42) = 2.54, p = 0.023] indicating a cadence-dependence of age-related differences in the muscular synergy between hip extensors and plantarflexors. The results demonstrate that in spite of a successful performance, children construct the task of pedaling differently when compared to adults, especially when they are pushed to their performance limits. The weaker synergy between hip extensors and plantarflexors suggests that a lack of inter-muscular coordination, rather than muscular power production per se, is a factor that limits children's performance ranges

    Distances from Surface Brightness Fluctuations

    Get PDF
    The practice of measuring galaxy distances from their spatial fluctuations in surface brightness is now a decade old. While several past articles have included some review material, this is the first intended as a comprehensive review of the surface brightness fluctuation (SBF) method. The method is conceptually quite simple, the basic idea being that nearby (but unresolved) star clusters and galaxies appear "bumpy", while more distant ones appear smooth. This is quantified via a measurement of the amplitude of the Poisson fluctuations in the number of unresolved stars encompassed by a CCD pixel (usually in an image of an elliptical galaxy). Here, we describe the technical details and difficulties involved in making SBF measurements, discuss theoretical and empirical calibrations of the method, and review the numerous applications of the method from the ground and space, in the optical and near-infrared. We include discussions of stellar population effects and the "universality" of the SBF standard candle. A final section considers the future of the method.Comment: Invited review article to appear in: `Post-Hipparcos Cosmic Candles', A. Heck & F. Caputo (Eds), Kluwer Academic Publ., Dordrecht, in press. 22 pages, including 3 postscript figures; uses Kluwer's crckapb.sty LaTex macro file, enclose

    On the Energy Transfer Performance of Mechanical Nanoresonators Coupled with Electromagnetic Fields

    Get PDF
    We study the energy transfer performance in electrically and magnetically coupled mechanical nanoresonators. Using the resonant scattering theory, we show that magnetically coupled resonators can achieve the same energy transfer performance as for their electrically coupled counterparts, or even outperform them within the scale of interest. Magnetic and electric coupling are compared in the Nanotube Radio, a realistic example of a nano-scale mechanical resonator. The energy transfer performance is also discussed for a newly proposed bio-nanoresonator composed of a magnetosomes coated with a net of protein fibers.Comment: 9 Pages, 3 Figure

    Holographic Metamagnetism, Quantum Criticality, and Crossover Behavior

    Full text link
    Using high-precision numerical analysis, we show that 3+1 dimensional gauge theories holographically dual to 4+1 dimensional Einstein-Maxwell-Chern-Simons theory undergo a quantum phase transition in the presence of a finite charge density and magnetic field. The quantum critical theory has dynamical scaling exponent z=3, and is reached by tuning a relevant operator of scaling dimension 2. For magnetic field B above the critical value B_c, the system behaves as a Fermi liquid. As the magnetic field approaches B_c from the high field side, the specific heat coefficient diverges as 1/(B-B_c), and non-Fermi liquid behavior sets in. For B<B_c the entropy density s becomes non-vanishing at zero temperature, and scales according to s \sim \sqrt{B_c - B}. At B=B_c, and for small non-zero temperature T, a new scaling law sets in for which s\sim T^{1/3}. Throughout a small region surrounding the quantum critical point, the ratio s/T^{1/3} is given by a universal scaling function which depends only on the ratio (B-B_c)/T^{2/3}. The quantum phase transition involves non-analytic behavior of the specific heat and magnetization but no change of symmetry. Above the critical field, our numerical results are consistent with those predicted by the Hertz/Millis theory applied to metamagnetic quantum phase transitions, which also describe non-analytic changes in magnetization without change of symmetry. Such transitions have been the subject of much experimental investigation recently, especially in the compound Sr_3 Ru_2 O_7, and we comment on the connections.Comment: 23 pages, 8 figures v2: added ref

    Maximum Likelihood Estimator for Hidden Markov Models in continuous time

    Full text link
    The paper studies large sample asymptotic properties of the Maximum Likelihood Estimator (MLE) for the parameter of a continuous time Markov chain, observed in white noise. Using the method of weak convergence of likelihoods due to I.Ibragimov and R.Khasminskii, consistency, asymptotic normality and convergence of moments are established for MLE under certain strong ergodicity conditions of the chain.Comment: Warning: due to a flaw in the publishing process, some of the references in the published version of the article are confuse

    Use of archival versus newly collected tumor samples for assessing PD-L1 expression and overall survival : an updated analysis of KEYNOTE-010 trial

    No full text
    Background: In KEYNOTE-010, pembrolizumab versus docetaxel improved overall survival (OS) in patients with programmed death-1 protein (PD)-L1-positive advanced non-small-cell lung cancer (NSCLC). A prespecified exploratory analysis compared outcomes in patients based on PD-L1 expression in archival versus newly collected tumor samples using recently updated survival data. Patients and methods: PD-L1 was assessed centrally by immunohistochemistry (22C3 antibody) in archival or newly collected tumor samples. Patients received pembrolizumab 2 or 10 mg/kg Q3W or docetaxel 75 mg/m2 Q3W for 24 months or until progression/intolerable toxicity/other reason. Response was assessed by RECIST v1.1 every 9 weeks, survival every 2 months. Primary end points were OS and progression-free survival (PFS) in tumor proportion score (TPS) 50% and 1%; pembrolizumab doses were pooled in this analysis. Results: At date cut-off of 24 March 2017, median follow-up was 31 months (range 23-41) representing 18 additional months of follow-up from the primary analysis. Pembrolizumab versus docetaxel continued to improve OS in patients with previously treated, PD-L1-expressing advanced NSCLC; hazard ratio (HR) was 0.66 [95% confidence interval (CI): 0.57, 0.77]. Of 1033 patients analyzed, 455(44%) were enrolled based on archival samples and 578 (56%) on newly collected tumor samples. Approximately 40% of archival samples and 45% of newly collected tumor samples were PD-L1 TPS 50%. For TPS 50%, the OS HRs were 0.64 (95% CI: 0.45, 0.91) and 0.40 (95% CI: 0.28, 0.56) for archival and newly collected samples, respectively. In patients with TPS 1%, OS HRs were 0.74 (95% CI: 0.59, 0.93) and 0.59 (95% CI: 0.48, 0.73) for archival and newly collected samples, respectively. In TPS 50%, PFS HRs were similar across archival [0.63 (95% CI: 0.45, 0.89)] and newly collected samples [0.53 (95% CI: 0.38, 0.72)]. In patients with TPS 1%, PFS HRs were similar across archival [0.82 (95% CI: 0.66, 1.02)] and newly collected samples [0.83 (95% CI: 0.68, 1.02)]. Conclusion: Pembrolizumab continued to improve OS over docetaxel in intention to treat population and in subsets of patients with newly collected and archival samples

    The Debrisoft ® monofilament debridement pad for use in acute or chronic wounds: A NICE medical technology guidance

    Get PDF
    As part of its Medical Technology Evaluation Programme, the National Institute for Health and Care Excellence (NICE) invited a manufacturer to provide clinical and economic evidence for the evaluation of the Debrisoft ® monofilament debridement pad for use in acute or chronic wounds. The University of Birmingham and Brunel University, acting as a consortium, was commissioned to act as an External Assessment Centre (EAC) for NICE, independently appraising the submission. This article is an overview of the original evidence submitted, the EAC’s findings and the final NICE guidance issued. The sponsor submitted a simple cost analysis to estimate the costs of using Debrisoft® to debride wounds compared with saline and gauze, hydrogel and larvae. Separate analyses were conducted for applications in home and applications in a clinic setting. The analysis took an UK National Health Service (NHS) perspective. It incorporated the costs of the technologies and supplementary technologies (such as dressings) and the costs of their application by a district nurse. The sponsor concluded that Debrisoft® was cost saving relative to the comparators. The EAC made amendments to the sponsor analysis to correct for errors and to reflect alternative assumptions. Debrisoft® remained cost saving in most analyses and savings ranged from £77 to £222 per patient compared with hydrogel, from £97 to £347 compared with saline and gauze, and from £180 to £484 compared with larvae depending on the assumptions included in the analysis and whether debridement took place in a home or clinic setting. All analyses were severely limited by the available data on effectiveness, in particular a lack of comparative studies and that the effectiveness data for the comparators came from studies reporting different clinical endpoints compared with Debrisoft®. The Medical Technologies Advisory Committee made a positive recommendation for adoption of Debrisoft® and this has been published as a NICE medical technology guidance (MTG17).The Birmingham and Brunel Consortium is funded by NICE to act as an External Assessment Centre for the Medical Technologies Evaluation Programme

    Holographic two dimensional QCD and Chern-Simons term

    Full text link
    We present a holographic realization of large Nc massless QCD in two dimensions using a D2/D8 brane construction. The flavor axial anomaly is dual to a three dimensional Chern-Simons term which turns out to be of leading order, and it affects the meson spectrum and holographic renormalization in crucial ways. The massless flavor bosons that exist in the spectrum are found to decouple from the heavier mesons, in agreement with the general lore of non-Abelian bosonization. We also show that an external dynamical photon acquires a mass through the three dimensional Chern-Simons term as expected from the Schwinger mechanism. Massless two dimensional QCD at large Nc exhibits anti-vector-meson dominance due to the axial anomaly.Comment: 22 page

    Fluctuating selection models and Mcdonald-Kreitman type analyses

    Get PDF
    It is likely that the strength of selection acting upon a mutation varies through time due to changes in the environment. However, most population genetic theory assumes that the strength of selection remains constant. Here we investigate the consequences of fluctuating selection pressures on the quantification of adaptive evolution using McDonald-Kreitman (MK) style approaches. In agreement with previous work, we show that fluctuating selection can generate evidence of adaptive evolution even when the expected strength of selection on a mutation is zero. However, we also find that the mutations, which contribute to both polymorphism and divergence tend, on average, to be positively selected during their lifetime, under fluctuating selection models. This is because mutations that fluctuate, by chance, to positive selected values, tend to reach higher frequencies in the population than those that fluctuate towards negative values. Hence the evidence of positive adaptive evolution detected under a fluctuating selection model by MK type approaches is genuine since fixed mutations tend to be advantageous on average during their lifetime. Never-the-less we show that methods tend to underestimate the rate of adaptive evolution when selection fluctuates
    corecore